Search results for "p 546 hicom 300 e h"
100 products found
Hicom 300E V2.0,2 Flexshelves, Licenses:328 operating-software,280 Starter Kit telephoning V1.0,34 Trunk / Networking V1.0,32 Comfort Package V1.0,10 Networking Basis V1.0, 1 Attendant Console V1.0,10 Chef- ...
The MB (Motherboard) 6/4 module board S30817-Q920-A701 is the central-control-module biard for the Hicom E 118. Starting at software-version V2.1, the module board is deployed in the Hicom 100E.
The MB (Motherboard) 4/4 module board S30817-Q920-B701 is the central-control-module for the Hicom E 112. The module board is deployed in the Hicom 100E starting at software-version V2.1.
The MB (Motherboard) 2/4 module board S30817-Q920-C701 MB2/4 is the central-control-module board for the Hicom E108. The module board is deployed in the Hicom 100E starting at software-version V2.1.
The CBMOD-module board is the central-control-module board for the Hicom 150E OfficePro, which enables all central control- and relaying functions.
The CBMOD-module board S30810-Q2960-X100 is the central-control-module board for the Hicom 150E OfficePro with a 2 MB DRAM-storage
The CBMOD module board S30810-Q2960-X200 is the central-control-module board for the Hicom 150E OfficePro has 4 MB DRAM-storage.
Die MUXU-Baugruppe ist eine Erweiterungsbaugruppe zur Anschaltung von Trading 300-, Dipatcher 300-,oder Executive 300-Arbeitsplätze. Eingesetzt wird die Baugruppe in Simens Hicom ...
Data Communication Link is a module board for the Hicom 300 / 300E and enables the connection between the control- and peripheral-connector-units LTU or the service-unit SU. ...
The TMOM-module board S30810-Q2014-X (Trunk Module Outgoing Multipurpose) has two connection sets for the activation of specialized operations within the Hicom 300.
The SLMD-module board S30810-Q2023-X200 is a Line Lock-out board with four digital subscriber-sets for the connection of ISDN-end-terminals via the U*-interface within the systems ...
Peripheral Clock Generator is a board for the Hicom 300/300E. The System Hicom is run synchronized.
Station Line Module Analog is a board for Hicom 300/300E and is the interface between the analog stations and the Hicom system.
Die Baugruppe SLMA (Station Line Module Analog) mit der Sachnummer S30810-Q2057 ist das Bindeglied zwischen den analogen Teilnehmern und dem System Hicom mit 16 Teilnehmerleitungen. ...
Trunk Module Outgoing Multipurpose
The TMX.21 (Digital Trunk Module) provides the adapter for the data traffic between the public data network IDN and the Hicom system as well as between Hicom and the terminals with ...
The TMACH-module board S30810-Q9556-X100 offers an analogue interface between the Hicom 300 system and the public network in Switzerland.
Power Supply for Hicom 300 E/H Cabinet-Design
Ring generator RGMOD for Hicom 300 E V3.0, Hicom 300 H V1.0 and the HiPath 4000.
The M2M-module board (Memory Module 2 MB) for the Hicom 300/300E is a dynamic storage unit with a capacity of 2 MB and is utilized as a common memory.
The CONF-module board S30810-Q2021-X (Conference Unit) for the Hicom 300 enables the activation of performance features such as die Leistungsmerkmale call-forwarding, call-waiting and ...
The MTS-module board S30810-Q2022-X (Memory Time Switch) for the Hicom 300/300E is utilized as the main-element within the digital wird als Grundelement des digitalen crossbar switch ...
The LTUC-module board S30810-Q2028-X (Line Trunk Unit Control) for the Hicom 300/300E which constitutes the interface between the transducer for the signaling-channel DCL, the ...
The SIU-module board S30810-Q2031-X (Signaling Unit) for the Hicom 300/300E, which provides the system with audbile tones, announcements and music-on-hold.
The RG-module board S30810-Q2058-X (Ring Generator) for the Hicom 300/300E generates an AC voltage of 65 V or 85 V with a frequency of 25 Hz or 50 Hz. The module board enables ...
The LCU-module board S30810-Q2093-X (Line Control Unit) enables the connection, via two available V.24-interfaces, of terminals and / or data processing equipment to the Hicom 300 ...
The M8M-module board (Memory Module 8 Mbyte) for the Hicom 300 / 300E is a dynamic storage unit with a storage capacity of 8 Mbyte which can be used as a common memory.
The MTS-module board S30810-Q2122-X (Memory Time Switch) for the Hicom 300/300E is utilized as the main-element within the digital wird als Grundelement des digitalen crossbar switch ...
The LTUC-module board S30810-Q2128-X (Line Trunk Unit Control) for the Hicom 300/300E which constitutes the interface between the transducer for the signaling-channel DCL, the ...
The MIP-module board S30810-Q2130-X (Memory- and Interface-Processor) functions within the System Hicom 300/300E as a signal exchange between the switching unit or SWU and a service ...
The MIP-module board S30810-Q2130-X200 (Memory- and Interface-Processor) functions within the System Hicom 300/300E as a signal exchange between the switching unit or SWU and a ...
The DPML-module board S30810-Q2149-X (Data Processor Multi/Local) for the Hicom 300 is the central control-processor of the SWU and the server.
The TMEM-module board S30810-Q2012-X (Trunk Module Bothway Current) has four full-duplex cross connection batches which manage the incoming as well as outgoing house-, trunk-, and ...
The TMBD (Trunk Module "Bundespost Deutschland") (4 circuits per module) can be used for signalling with main station interfaces (MOSIG) as well as for direct inward dialing with the ...
The TMBP-module board S30810-Q2032-X (Trunk Module Bothway Inter PBX Simultaneous) has four dual-connection sets for incoming and outgoing signals between two sub-systems.
The SLMB-module board S30810-Q2052-X (Station Line Module Burstsystem) offers 8 U 200-interfaces which enable the connection of system-specific end terminals and the attendant ...
The TMEMW-module board S30810-Q2092-X (Trunk Module Ear & Mouth/World) has four dual-interconnection sets E&M for incoming and outgoing signals between the main- and ...
The DIUS2-moduleboard S30810-Q2096-X Digital Interface Unit ISDN is intended forthe Siemens Hicom 300. The module board has a digital S 2-interfacefor ISDN.
The DIUS2-module board S30810-Q2096-X200 (Digital Interface Unit ISDN) is intended for the Siemens Hicom 300 and HiPath 4000. The module board has a digital S 2-interface for ...
The MBU-module board S30810-Q2114-X (Message Buffer Unit) with signal exchange controls the signal- and data-traffic between switching unit (SWU), the peripheral unit (LTGs) and the ...
The SLMB-module board S30810-Q2150-X (Station Line Module Burstsystem) offers 16 U 200-interfaces which enable the connection of system-specific end terminals and the attendant ...
The DSC80 board for the Hicom 310 E and Hicom 330 E, unites all features that a central control unit of a Hicom 300 System requires, onto a single board.
Diese Baugruppe vereint auf einer Leiterplatte alle Leistungsmerkmale, die die Zentralsteuerung eines Hicom 300 Systems benötigt.
The SLOP2-module board S30810-Q2180-X (Power SLMO) for the Hicom 300 has 24 Up0/E-interfaces for the connection of system specific telephones.
The MTS64-module board (Memory Time Switch) realizes the space-time-crossbar-switch for the Hicom 300.
The NCG-module board (Network Clock Generator) generates the internal clock and in order to synchronize it can receive reference clock signals from the trunk-modules TMX.21, TMD, ...
C39228-A7195-A11 Adapter SIVAPAC/SIPAC
Inverter for Hicom 300E
The SLMU-module board S30810-Q2115-X (Station Line Module Digital U P0) enables the connection via 16 U P0-interfaces of Siemens SET 551 or PNTs telephones.
The Station Line Module Digital S0 board SLMS allows 8 S0-Interfaces the connection of up to 8 digital terminal per port.
The Stream Control Central board SCC for Hicom 300/300E, is the interface between the central Processor DM80 and the peripheral boards of the Hicom 3X3. ...
The IOPA-module board S30810-Q2155-X (Input-Output Processor SCSI and Alarm-Control) enables the activation of the peripheral storage (CT / HD) within the servers.
The IOPAX-module board S30810-Q2255-X (Input-Output Processor SCSI and Alarm-Control) enables the control of the peripheral storage unit (CT,HD) within the server.
The SLMT board is an extension board for Hicom Trading. The board is used with the Hicom 300/300E system.
The MD-module board S30050-Q2026-X (Message Distributor) has the following functions within the Hicom 390.1/391.1 system; multiplexes or de-multiplexes the HDLC-data-lines between the ...
The central clock generator (CCG) in the Hicom 390.1 system provides the users with the reference clock signals CKAREF (2048 Mhz) and FMBREF (4-kHz synchronizing pulse).
The DM4L-module board S30810-Q2260-X (Data Processor 486 Mono with LAN) offers the functions of a DM3L-module board, while providing the systems Hicom 330E and Hicom 350E with a ...
The DM4L-module board S30810-Q2260-X (Data Processor 486 Mono with LAN) offers the functions of a DM3L-module board, while providing the systems Hicom 330E and Hicom 350E with a ...
Power Supply for Hicom300 E
Inverter for Hicom 300
Netzteil für Hicom 300
Power Supply forHicom 300
powersupplyfor Hicom 300 H
Inverterfor Hicom 300 E
Power Supply for Hicom 300 and HiPath 4000
Power Supply for Hicom 300 E.
The DM3L-module board S30807-Q2230-X500 (Data Processor 386 Mono with LAN) is an alternative variant of the module board; S30807-Q2230-X for the Hicom 300/300E.
Board for the Common Control Universal Server (CCUS) from Siemens. Compatible to Hicom 300 E V3.1.
The TMBCT-module board S30810-Q2111-X100 (Trunk Module Bothway Current) offer four interface according to alternate current / audio frequency -recognition-procedures, which is the ...
The LCS0-module board S30810-Q2120-X enables via 2 S 0-ports the connection of terminals to the Hicom 300.
The TMBCT-module board S30810-Q2111-X (Trunk Module Bothway Current) has four dual-AC-cross-connection-sets (QS-WES) which can connect two sub-systems.
The Data Processor 486 board DP486 for Hicom 300/300E, is the central control processor of the SWU and the server. The board is fully pin- and SW-compatible with its forerunners DPML, ...
The Data Processor 386 Dynamic Memory board DP3DM (16 MB) is the central control processor of the SWU and the server.
The DDCL (Double Data Communication Link) for Hicom 300/300E, provides the signaling interface between the LTUs and the DP in the SWU.
The Data Processor 386 Mono DM3L-X for the Hicom 300/300E, is a subclass of the DM3L-X, and enables the functions of the DM80-data-processor for the 80CM.
The DM3L-module board S30807-Q2230-X100 (Data Processor 386 Mono with LAN) is a variation of theS30807-Q2230-X module board for the Hicom 300/300E.
The Input Output Controller Switching Network (IOCSN) belongs to the central boards and together with a NCG and up to 7 MTS64 a breakdown unit.
The TRIM (System Module Tape Interface) board is a peripheral board for the Hicom 300/300E.
Die SLMY-Baugruppe ist eine Erweiterungsbaugruppe, die den Anschluss von max. 120 Leitungen und max. 30 Trading-Arbeitsplätzen ermöglicht. Eingesetzt wird die Baugruppe in Simens ...
The QDCL-module board S30810-Q2113-X (Quad Data Communication Link) for the Hicom 350E serves as an interface between the peripheral and the central data-processor DP (DP4L or DM3L). ...
The QDCL-module board S30810-Q2113-X (Quad Data Communication Link) for the Hicom 350E is the interface between the peripheral- and the central data processing-unit DP (DP4L or DM3L). ...
The SLMO-module board S30810-Q2158-X (Subscriber Line Module U P0/E Interface) forms the link between the system specific telephones and the Hicom 300E system.
Power Supply for Hicom 310E
Power Supply for Hicom 300E
The IOCG is used with the Hicom 390 systems and is a component of the group processor (GP) (DP/LTG). It contains the input/output control for the line trunk group (LTG) and the clock ...
The Input Output Controller module board IOC is deployed within the Hicom 391.3 system. The module board functions as an input-/output-control-unit or as an input-/output-control-unit ...
The Signaling Unit, SIUX2 board is a replacement for the SIU-board in the central and peripheral frames.
The Line Control/Line Bus Control, LBU-board for the Hicom 300/300E allows the connection of terminals and/or data-processing-systems over two frontsided V.24-interfaces.
The Memory Time Switch and Clock, MTSCG-board is a central board. the board units the functionality of a MTS64- or a MTS128-coupling field (Memory Time Switch) and a NCG (Network ...
The Data Processor 486 with LAN Node (DP4L) is based on the DP486 board. The board is compatible with the DM3L.
The Hicom internal application server DMP5L with the SW platform for clien/server applications can be used as of Hivom V2.0. The DMP5L serves as internal server platform either for ...
Analog trunk line for Hicom 300
The power supplyframe PSR930E is a UACD-extension box for the electric supply framePSR930.
Power Supply for PSR930
UACD-Powerbox for 19" Racks
IN: DC 42V/7,8A; -58V/5,7A max 240W. OUT:DC 5V/40A; -5V/6A 12V/8A; -12V/1A
Inverter forHicom 300 E