Search results for "p 435 hicom 100 e"
100 products found
The Ultraset Memory 100 is a Comort telephone with a lot of performance features.
The MB (Motherboard) 6/4 module board S30817-Q920-A701 is the central-control-module biard for the Hicom E 118. Starting at software-version V2.1, the module board is deployed in the Hicom 100E.
The MB (Motherboard) 4/4 module board S30817-Q920-B701 is the central-control-module for the Hicom E 112. The module board is deployed in the Hicom 100E starting at software-version V2.1.
The MB (Motherboard) 2/4 module board S30817-Q920-C701 MB2/4 is the central-control-module board for the Hicom E108. The module board is deployed in the Hicom 100E starting at software-version V2.1.
The CBMOD-module board is the central-control-module board for the Hicom 150E OfficePro, which enables all central control- and relaying functions.
The CBMOD-module board S30810-Q2960-X100 is the central-control-module board for the Hicom 150E OfficePro with a 2 MB DRAM-storage
The CBMOD module board S30810-Q2960-X200 is the central-control-module board for the Hicom 150E OfficePro has 4 MB DRAM-storage.
Hicom 300E V2.0,2 Flexshelves, Licenses:328 operating-software,280 Starter Kit telephoning V1.0,34 Trunk / Networking V1.0,32 Comfort Package V1.0,10 Networking Basis V1.0, 1 Attendant Console V1.0,10 Chef- ...
Special hands-free talking Microphone and Speaker, Echo Suppression
Special hands-free talking Microphone and Speaker, Echo Suppression
Special hands-free talking Microphone and Speaker, Echo Suppression
Special hands-free talking Microphone and Speaker, Echo Suppression
Special hands-free talking Microphone and Speaker, Echo Suppression
The Optiset E Advance is a comprehensive comfort-telephone compatible with all Siemens Hicom- & HiPath telephone systems.
The Optiset E Advance is a feature-packed comfort telephone for all Siemens Hicom and HiPath telephone systems.
The Optiset E Advance is a feature-packed comfort telephone for all Siemens Hicom and HiPath telephone systems.
The Optiset E Advance is a feature-packed comfort telephone for all Siemens Hicom and HiPath telephone systems.
Das Optiset E Advance plus ist ein umfangreich ausgestattetes Komforttelefon mit Freisprechfunktionfür alle Siemens Hicom- & Hipath Telefonanlagen.
The Optiset E Advance Plus is a feature-packed phone with hands-free convenience for all Siemens Hicom and HiPath telephone systems.
Das Optiset E Advance plus ist ein umfangreich ausgestattetes Komforttelefon mit Freisprechfunktionfür alle Siemens Hicom- & Hipath Telefonanlagen.
The Optiset E Basic telephone is the comfortable entry-level model with eight function keys, compatible with all Siemens Hicom- & Hipath telephone systems.
The Optiset E Basic Phone is the convenient entry-level model with 8 function keys for all Siemens Hicom and HiPath telephone systems.
The Optiset E Basic Phone is the convenient entry-level model with 8 function keys for all Siemens Hicom and HiPath telephone systems.
The Optiset E Basic Phone is the convenient entry-level model with 8 function keys for all Siemens Hicom and HiPath telephone systems.
The Optiset E Basic Phone is the convenient entry-level model with 8 function keys for all Siemens Hicom and HiPath telephone systems.
The Optiset E Entry telephone is the comfortable entrylevel model for all Siemens Hicom- & Hipath telephone systems.
Das Optiset E Entry Telefon ist das komfortable Einstiegsmodell für alle Siemens Hicom- & Hipath Telefonanlagen.
The Optiset E Entry Phone is a convenient entry model for all Siemens Hicom and HiPath telephone systems.
Das Optiset E Entry Telefon ist das komfortable Einstiegsmodell für alle Siemens Hicom- & Hipath Telefonanlagen.
The Optiset E Memory is a comfort-telephone with integrated note-pad function compatible to all Siemens Hicom- & Hipath telephone systems.
Suitable for analog adapter on Optiset E, optiPoint 4xx/5xx/6xx and T-Com Octophon 2x phones
Suitable for analog adapter on Optiset E, optiPoint 4xx/5xx/6xx and T-Com Octophon 2x phones
Suitable for analog adapter on Optiset E, optiPoint 4xx/5xx/6xx and T-Com Octophon 2x phones
Suitable for analog adapter on Optiset E, optiPoint 4xx/5xx/6xx and T-Com Octophon 2x phones
The followingproduct enables the connection of two Optiset E terminals Slavetelephone, RJ11, which is recognized by the system as a independantEG with a seperate telephone number and an individual B-channel.
Siemens Optiset E Speech Adapter
C39363-A7007-A5 cradle with Optiset E handset for AC-Win operator console
C39363-A7007-C4 cradle with Optiset E handset for AC4 operator console
Das Optiset E Memoryist ein Komforttelefon mit integrierter Notizbuchfunktion für alle Siemens Hicom- & Hipath Telefonanlagen.
Das Optiset E Memoryist ein Komforttelefon mit integrierter Notizbuchfunktion für alle Siemens Hicom- & Hipath Telefonanlagen.
Das Optiset E Memoryist ein Komforttelefon mit integrierter Notizbuchfunktion für alle Siemens Hicom- & Hipath Telefonanlagen.
Das Optiset E Memoryist ein Komforttelefon mit integrierter Notizbuchfunktion für alle Siemens Hicom- & Hipath Telefonanlagen.
The Siemens Optiset E Standardmodel offers hands-free operation and open listening.
The Optiset E Standard telephone is a standard model for all Siemens Hicom- and Hipath telephone systems.
The SiemensOptiset E Standard model offers hands-free operation and open listening.
The SLMB-module board S30810-Q2052-X (Station Line Module Burstsystem) offers 8 U 200-interfaces which enable the connection of system-specific end terminals and the attendant ...
The SLMB-module board S30810-Q2150-X (Station Line Module Burstsystem) offers 16 U 200-interfaces which enable the connection of system-specific end terminals and the attendant ...
The TMX.21 (Digital Trunk Module) provides the adapter for the data traffic between the public data network IDN and the Hicom system as well as between Hicom and the terminals with ...
Data Communication Link is a module board for the Hicom 300 / 300E and enables the connection between the control- and peripheral-connector-units LTU or the service-unit SU. ...
The TMOM-module board S30810-Q2014-X (Trunk Module Outgoing Multipurpose) has two connection sets for the activation of specialized operations within the Hicom 300.
The SLMD-module board S30810-Q2023-X200 is a Line Lock-out board with four digital subscriber-sets for the connection of ISDN-end-terminals via the U*-interface within the systems ...
Peripheral Clock Generator is a board for the Hicom 300/300E. The System Hicom is run synchronized.
Station Line Module Analog is a board for Hicom 300/300E and is the interface between the analog stations and the Hicom system.
Die Baugruppe SLMA (Station Line Module Analog) mit der Sachnummer S30810-Q2057 ist das Bindeglied zwischen den analogen Teilnehmern und dem System Hicom mit 16 Teilnehmerleitungen. ...
The NCG-module board (Network Clock Generator) generates the internal clock and in order to synchronize it can receive reference clock signals from the trunk-modules TMX.21, TMD, ...
Trunk Module Outgoing Multipurpose
AC/DC Wandler derFirma SYSKAB
The MD-module board S30050-Q2026-X (Message Distributor) has the following functions within the Hicom 390.1/391.1 system; multiplexes or de-multiplexes the HDLC-data-lines between the ...
The TMEM-module board S30810-Q2012-X (Trunk Module Bothway Current) has four full-duplex cross connection batches which manage the incoming as well as outgoing house-, trunk-, and ...
The TMBD (Trunk Module "Bundespost Deutschland") (4 circuits per module) can be used for signalling with main station interfaces (MOSIG) as well as for direct inward dialing with the ...
The TMBP-module board S30810-Q2032-X (Trunk Module Bothway Inter PBX Simultaneous) has four dual-connection sets for incoming and outgoing signals between two sub-systems.
The central clock generator (CCG) in the Hicom 390.1 system provides the users with the reference clock signals CKAREF (2048 Mhz) and FMBREF (4-kHz synchronizing pulse).
The TMEMW-module board S30810-Q2092-X (Trunk Module Ear & Mouth/World) has four dual-interconnection sets E&M for incoming and outgoing signals between the main- and ...
The DIUS2-moduleboard S30810-Q2096-X Digital Interface Unit ISDN is intended forthe Siemens Hicom 300. The module board has a digital S 2-interfacefor ISDN.
The DIUS2-module board S30810-Q2096-X200 (Digital Interface Unit ISDN) is intended for the Siemens Hicom 300 and HiPath 4000. The module board has a digital S 2-interface for ...
The MBU-module board S30810-Q2114-X (Message Buffer Unit) with signal exchange controls the signal- and data-traffic between switching unit (SWU), the peripheral unit (LTGs) and the ...
The DSC80 board for the Hicom 310 E and Hicom 330 E, unites all features that a central control unit of a Hicom 300 System requires, onto a single board.
Diese Baugruppe vereint auf einer Leiterplatte alle Leistungsmerkmale, die die Zentralsteuerung eines Hicom 300 Systems benötigt.
The SLOP2-module board S30810-Q2180-X (Power SLMO) for the Hicom 300 has 24 Up0/E-interfaces for the connection of system specific telephones.
The MTS64-module board (Memory Time Switch) realizes the space-time-crossbar-switch for the Hicom 300.
The DM4L-module board S30810-Q2260-X (Data Processor 486 Mono with LAN) offers the functions of a DM3L-module board, while providing the systems Hicom 330E and Hicom 350E with a ...
The DM4L-module board S30810-Q2260-X (Data Processor 486 Mono with LAN) offers the functions of a DM3L-module board, while providing the systems Hicom 330E and Hicom 350E with a ...
The TMACH-module board S30810-Q9556-X100 offers an analogue interface between the Hicom 300 system and the public network in Switzerland.
C39228-A7195-A11 Adapter SIVAPAC/SIPAC
Power Supply for Hicom 300 E/H Cabinet-Design
Inverter for Hicom 300E
Ring generator RGMOD for Hicom 300 E V3.0, Hicom 300 H V1.0 and the HiPath 4000.
The M2M-module board (Memory Module 2 MB) for the Hicom 300/300E is a dynamic storage unit with a capacity of 2 MB and is utilized as a common memory.
The CONF-module board S30810-Q2021-X (Conference Unit) for the Hicom 300 enables the activation of performance features such as die Leistungsmerkmale call-forwarding, call-waiting and ...
The MTS-module board S30810-Q2022-X (Memory Time Switch) for the Hicom 300/300E is utilized as the main-element within the digital wird als Grundelement des digitalen crossbar switch ...
The LTUC-module board S30810-Q2028-X (Line Trunk Unit Control) for the Hicom 300/300E which constitutes the interface between the transducer for the signaling-channel DCL, the ...
The SIU-module board S30810-Q2031-X (Signaling Unit) for the Hicom 300/300E, which provides the system with audbile tones, announcements and music-on-hold.
The RG-module board S30810-Q2058-X (Ring Generator) for the Hicom 300/300E generates an AC voltage of 65 V or 85 V with a frequency of 25 Hz or 50 Hz. The module board enables ...
The LCU-module board S30810-Q2093-X (Line Control Unit) enables the connection, via two available V.24-interfaces, of terminals and / or data processing equipment to the Hicom 300 ...
The M8M-module board (Memory Module 8 Mbyte) for the Hicom 300 / 300E is a dynamic storage unit with a storage capacity of 8 Mbyte which can be used as a common memory.
The QDCL-module board S30810-Q2113-X (Quad Data Communication Link) for the Hicom 350E serves as an interface between the peripheral and the central data-processor DP (DP4L or DM3L). ...
The QDCL-module board S30810-Q2113-X (Quad Data Communication Link) for the Hicom 350E is the interface between the peripheral- and the central data processing-unit DP (DP4L or DM3L). ...
The SLMU-module board S30810-Q2115-X (Station Line Module Digital U P0) enables the connection via 16 U P0-interfaces of Siemens SET 551 or PNTs telephones.
The Station Line Module Digital S0 board SLMS allows 8 S0-Interfaces the connection of up to 8 digital terminal per port.
The MTS-module board S30810-Q2122-X (Memory Time Switch) for the Hicom 300/300E is utilized as the main-element within the digital wird als Grundelement des digitalen crossbar switch ...
The LTUC-module board S30810-Q2128-X (Line Trunk Unit Control) for the Hicom 300/300E which constitutes the interface between the transducer for the signaling-channel DCL, the ...
The MIP-module board S30810-Q2130-X (Memory- and Interface-Processor) functions within the System Hicom 300/300E as a signal exchange between the switching unit or SWU and a service ...
The MIP-module board S30810-Q2130-X200 (Memory- and Interface-Processor) functions within the System Hicom 300/300E as a signal exchange between the switching unit or SWU and a ...
The Stream Control Central board SCC for Hicom 300/300E, is the interface between the central Processor DM80 and the peripheral boards of the Hicom 3X3. ...
The DPML-module board S30810-Q2149-X (Data Processor Multi/Local) for the Hicom 300 is the central control-processor of the SWU and the server.
The IOPA-module board S30810-Q2155-X (Input-Output Processor SCSI and Alarm-Control) enables the activation of the peripheral storage (CT / HD) within the servers.
The SLMO-module board S30810-Q2158-X (Subscriber Line Module U P0/E Interface) forms the link between the system specific telephones and the Hicom 300E system.