Power supply for Hicom 150E Office One, Hipath 3150 and HiPath 3250.
Power supply for Hicom 116.
The Music-on-Hold-module board musiphone MPPI enables the integration of music while subscribers are on-hold.
Power Supply for Hipath 3000 Wallmount-PBX with battery manager
Main Power Supply for OpenScape Business X3W und X5W
Power Supply for Hipath 3000 Wallmount-PBX with battery manager
AC/DC Wandler derFirma SYSKAB
Integrated Voicemail-function for HiPath Xpressions Compact starting with V2.5
Integrated Voicemail-function for HiPath Xpressions Compact starting with V2.5
Integrated Voicemail-function for HiPath Xpressions Compact starting with V2.5
Announcement and music on hold functions for HiPath 3x00
The switch-module board which enables the external music input to the telephone systems HiPath 3300 and HiPath 3500.
Power Supply forHiPath 4000 V2.0 inCSPCI-Shelf andSurvivability Server
InverterforHiPath 4000 V2.0 inCSPCI-Shelf andSurvivability Server
Power Supply for HiPath 540 / HiPath 580
Suitable for OpenStage, optiPoint, Octophon F
Suitable for OpenStage, optiPoint, Octophon F
The power supply unit S30122-K5051-X100 is deployed with the Hicom 200.
The PSU2 power supply S30122-K5449-X312 supplies the Hicom 118 with the following required voltage 5V DC, -48V DC and the call-voltage of 75Veff with 25Hz.
Power Supply for Hipath 3000 Wallmount-PBX with battery manager
The PSUC power supply S30122-K5661-M provides Siemens telephone systems with the required following voltage of 5V DC, -48V DC and the call-voltage of 75Veff .
Power Supply for Hicom 300 E/H Cabinet-Design
Ring generator module RGMOD for Hicom 300 und HiPath 4000
Ring generator module RGMOD for Hicom 300 und HiPath 4000
Battery Box 4x12V/7Ah for Hipath systems
Power Supply for HiPath 540 / HiPath 580
Power Supply for HiPath 540 / HiPath 580
Mainboard for HiPath OpenOffice
The Hicom Office PhoneMail Entry B-module-board S30122-Q7078-X for the Hicom150E and Hipath 3000 systems.
Voicemail board 8-channel including 30 GB harddrive for HiPath 3350
The SLAS8-module board S30122-Q921-C301 is a subscriber-replacement-board with eight analogue interfaces for the connection of system-neutral terminals.
Supports four ISDN Basic Rate Interfaces BRIs
The UAM-9610N-module board S30122-X7217-B is an optional module board for the activation of announcement and music on hold functions for the communication systems HiPath 3350 and HiPath 3550, which can be connected ...
The UAM-module board S30122-X7217-X is an optional module board for the activation of announcement and music on hold functions for the communication systems HiPath 3350 and HiPath 3550, which can be connected to ...
Outdoor Box for DECT Base Stations without heating unit
Outdoor Box for DECT Base Stations without heating unit
Outdoor Box for DECT Base Stations without heating unit
Power Supply for OpenScape Business X1
Central Processor Board for HiPath 4000 - Data and Switch Processor for Compact PCI/LAN
S30122-K7754-X OpenScape 4000 Eco Server
Central Processor Board for HiPath 4000 - Data and Switch Processor for Compact PCI/LAN
Central Processor Board for HiPath 4000 - Data and Switch Processor for Compact PCI/LAN
Central Processor Board for HiPath 4000 - Data and Switch Processor for Compact PCI/LAN
Data backup carrier slot for OpenScape 4000 V7.0
IN: 110/220V; 60/50 HZ. OUT: -48V/5A; -5V/2A; +5V/20A; +12V/4.5A; +69V/0.3A
Inverter for Hicom 300
IN: 115/230V; 50-60HZ;400/392W. OUT: +5V/9A; -5V/1.1A; +12V/2.1A; -48V/3A; -60V/0.1A; +26V/3A; -12V/0.1A 60/75 VAC /60mA(200mA)
Power Supply for Siemens PNT-E
Power Supply for Siemens PNT-E
Netzteil für Hicom 300
IN:AC 110V/240V; 4A/2A 50,60 Hz; DC 320/380V 2A. OUT DC: 5.1V/12A; -5.1V/0.5A; +12V/1.9A; -12V/0.1A; -48V/2.5A; 380V/ 0.3A; AC: 60/75V, 4/8VA 20/25/50 HZ
115/230V, 4.4A/2.3A 50-60Hz OUT: AC: 75V/25 Hz/16W; +5,1V 4A; +5,1V 7A; -5.1V/0,6A; +12V/1,2A; -12V/0,1A; +26V/1.6A; -48V/1.3A
115/230V, 4.0A/2.2A 50-60Hz OUT: AC: 75V, 25 Hz, 16W; +5,1V 4A; +5,1V 7A; -5.1V/0,6A; +12V/1,2A; -12V/0,05A; +26V/1.6A; -48V/1.3A
IN: 115/230V, 3.8A/1.9A 50-60HZOUT: AC: 380V, 0.2 A; +5.1V 12A; +5.1V 3A; -5V/0.5A; +12V/1.9A; -12V/0.1A; -48V/2.5A; -48V/0.25A
Power supply for Hicom 125. IN: 380V 0,2A, -48V 6A. OUT DC: +53,3/55V 1,2A; 320V 275W
IN;115/230V; 3/1,8A; 50/60 HZOUT AC: 60/75 VAC,20/25 HZ 8W; DC: +5,1V/3A; +5,1V/7A; -5,1V/0,6A; +12V/1,2A; -48V/2A; -12V/0,1A
Power Supply forHicom 300
power supply for Hicom 116 expansion stage 2/3/4. IN:230V/0.5A / 50/60HZ. OUT: +36V/1A; +5.1V/1.2A
Power supply for Hicom 112. IN: 98/264V 0.5/0.19A 50/60HZ. OUT: 5V/2A; -48V/420mA; 75VAC 20HZ/4VA
Power supply for Hicom 112. IN: 98/264V 0.5/0.19A 50/60HZ 24VDC/3A OUT: 5V/2A; -48V/420mA; 75VAC 25HZ/4VA
Power supply for Hicom 118. IN: 98/264V 1.37-0.51A 50-60HZ +24VAC/4A. OUT: 5V/2.5A; -48V/1.1A; 75VAC 25HZ/8VA
Power supply for Hicom 118. IN: 98/264V 1.37-0.51A 50-60HZ +24VAC/4A. OUT: 5V/2.5A; -48V/1.1A; 75VAC 25HZ/8VA
IN: 115/230V; 0,6/0,4A; 50-60HZOUT: +5,1V/3A; -48V/0,4A; 75VAC 20/25/50HZ, 4W. The power suply is used with the Hicom 150 OfficePoint and Hipath 3350.
OUT: +5V, -5V; -12V, +12V; -60V
Power Supply for Hicom 310E
IN: 115-230VAC 5,4-2,7A 50/60HZOUT: +5,1V/12A; -5,1V/0,5A; -55,2V/3Amax (75VAC 0,06A)
IN: 115-230VAC 5,4-2,7A 50/60HZOUT: +5,1V/12A; -5,1V/0,5A; -55,2V/3Amax (75VAC 0,06A)
Inverter for Hicom 300E
IN 115/230VAC 5/3A50-60HZ OUT 54,7/-53,3 V DC 3,7/6A 65/75 V AC / 85 V AC 5VA/5VAmax 500/585W
IN: -48VDC/5AOUT: +5,1V/16A; -5,1V/12A; +12V/2,5A
IN: 180/240VAC/3A 45-66HZ; 54,7VDC/8,7AOUT: -54V/5,3A -54V/3,3A; -54V/8,7A
Power Supply for Hicom 300E
powersupplyfor Hicom 300 H
Inverterfor Hicom 300 E
Power Supply UPSC-DR for HiPath 3300 and HiPath 3500
The Voicemail-module-board encompasses 8 channel / ports and a 30 GB harddrive in which up to 100 Auto Attendant Mailboxes as well as up to 100 Information-Mailboxes can be saved.
Power Supply for Hicom 300 and HiPath 4000
Power Supply for Hicom 300 E.
Power Supply forHiPath 4000 V2.0 in CSPCI-Shelf and Survivability Server
Inverter for HiPath 4000 V2.0 in CSPCI-Shelf and Survivability Server
Power Supply for HiPath 3800 and AP 3700 IP
Memory Time Switch (MTS) is the base of the switching network for Hicom 200.
The Station Line Modul Burstsystem board (SLMB16), the user connection for burst procedure (U200-Interface), is used to connect digital devices and the switching terminal AC2.
The TMID 8 is an expansion board for the Siemens Hicom 200 telephone system with 8 impulse signal trunk line.
The Voicemail-module-board for voice storage Voice Mail Module, music on hold and automatic centralized storage is intended for the HiPath 3350 and HiPath 3550.
Voice Mail Module, music-onhold and an automatic centralized storage for Hipath 3700 and HiPath 3750
Voicemail-module-board with voice storage (Voice Mail Modul), musik on hold and automatic centralized storage is intended for the HiPath 3700 and HiPath 3750.
The Voicemail-module-board for the voice storing (Voice Mail Module), with integrated music on hold and announcements for the HiPath 3800.
For BS/2, BS2/3, BS3/1, BS3/3, BS4, including Heating
The Phonemail Version 2.0 only works with the Hicom 150E OfficeCom/Point H1.2 andnot on the 3.0or 4.0.
Power Supply UPSC-DR for HiPath 33/3500 and OpenScape Business X3R/X5R systems
Power Supply UPSC-DR for HiPath 33/3500 and OpenScape Business X3R/X5R systems
The Phonemailboard has 8 channels ports and one 30 GB Harddrive forthe saving of up to 100 auto attendant mailboxes and up to 100informations mailboxes.
The Phonemailboard has 8 channels ports and one 30 GB Harddrive forthe saving of up to 100 auto attendant mailboxes and up to 100informations mailboxes.
This product is deployed with theHiPath 4000 system starting at software version 5.0
The MOD-drive is a magnetic optical drive measuring 3,5" with the Siemens item code number S30122-X5716-X and S30122-K7158-X.
The MOD-drive is a magnetic optical drive measuring 3,5" with the Siemens item code number S30122-X7635-X and S30122-K7635-X100.
This product is deployed within the HiPath 4000 system starting with the software version 5.0.
The MOD-drive, is a magnetic optical drive measuring 3,5" with the Siemens item code number S30122-X7415-X and S30122-K7414-X100.